MODEL : BCAL 40
Body mode: 20 to 50°C / 68 to 122°F
Surface mode: 0 to 100°C / 32 to 212°F
Extension tube gives better uniformity and avoid losses due to ambient temperature and air movement
- Introduction
- Specifications
- Key Features
- Accessories
Product Details
SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body.
Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature.
BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual.
| Model | BCAL 40 |
|---|---|
| Display | 3.5 inch True TFT Display with Touch Screen |
| Temperature Range | Body mode: 20 to 50°C / 68 to 122°F Surface mode: 0 to 100°C / 32 to 212°F |
| Resolution | 0.01°C |
| Stability | ±0.03 °C |
| Uniformity | ± 0.3°C |
| Stabilization Time | 10 minutes |
| Temperature readout | °C & °F at a time |
| Heating time | 10 mins (Amb. To 50°C ) |
| Power supply | 90 to 260V AC/DC / 50/60Hz |
| Power Consumption | Less than 100 VA |
| Aperture area | 25mm |
| Emissivity | 0.950 |
| Overall Dimension | 210 x 210 x 140 (L x B x H)(Approx.) |
| Instrument Weight | 3.7 kg |
Note: Due to continuous product improvements, Published specifications may change with out notice
3.5 inch True TFT display with Touch screen
Range from 20 to 50°C / 68 to 122°F @ Body mode
Range from 0 to 100°C / 32 to 212°F @ surface mode @Amb.25°C
Extension tube gives better uniformity and avoid losses due to ambient temperature and air movement
Indicates both °C & °F at a time
Stable to ± 0.03°C
Accurate better than ± 0.3°C
Portable, Rugged & Onsite carryable
Standard Accessories
- 1.Basic Instrument
- 2.Spare Fuses
- 3.Instruction manual
- 4.Mains card
- 5.Small extension tube
- 6.Large extension tube
- 7.Carry bag
Optional Accessories
- 1.Carrying case
- 2.ISO/IEC 17025 Accredited calibration certificate