SANSEL Instruments and Controls
is a leading organization
that has established |
|
 |
|
|
|
 |
|
Water Treatment Plant
Textile Mills
Sugar mill
Pharmaceutical |
|
 |
|
|
|
 |
|
Please feel free to Contact Us for
Enquiry
|
|
 |
|
|
|
|
|
|
Products
>
Time
Controllers |
|
|
| Timer |
|
Model DT-270 /
DT-240 |
|
|
|
FEATURES |
 |
Three Digit Thumb wheel type. |
|
 |
Time, Memory Backup, pulse start
and delay modes are selectable by Dip switch. |
|
 |
7 Selectable Timing Range:
9.99sec, 99.9sec, 999sec, 99.9min, 999min, 99.9hrs & 999hrs. |
|
 |
Down Counting |
 |
10 years Run time memory Backup |
 |
Selectable ON Delay/OFF Delay
mode. |
|
 |
opto Isolated pulse start& Reset
ON rear terminal. |
 |
High Accuracy. |
 |
Universal supply 90 to 270V AC. |
 |
DPDT Relay output. |
|
|
|
|
|
SPECIFICATIONS |
|
Model |
DT 270 |
DT 240 |
|
Dimension |
72mmx72mmx110mm |
48mmx48mmx90mm |
|
Cutout Dimension |
68x68mm |
44x44mm |
|
Display |
0.5” 7 segment L.E.D |
0.3” 7 Segment L.E.D |
| |
|
Input
Accuracy |
±0.25% |
|
Range
|
Selectable By
9.99Sec
Dip Switch
99.9Sec
999Sec
99.9Min
999Min
99.9Hrs
999Hrs |
|
Memory Back up |
10 years Run time holding Memory Back up. |
|
Time
Setting |
By3 Digit Thumbwheel switch |
|
Delay Mode |
ON Delay, OFF Delay selectable By Dip
switch |
|
Start |
Power on start, pulse start selectable.
(Rear Terminal) |
|
Reset Input |
Front panel Reset(3 Sec), Rear terminal
opto isolated Reset and power on reset. |
|
Counting Direction |
Down Counting |
|
STATUS Indication |
Relay on L.E.D |
|
Relay Output |
DPDT, 5A, 230V AC |
|
Supply |
90 to 270V AC, 50 Hz. |
|
Operating Temp& Humidity |
0 to 500C / 90% RH |
|
|
|
|
Top |
| Time
Controllers |
|
Model DT-271 /
DT-241 |
|
| |
|
FEATURES |
 |
Set & Preset value Indication by
dual display. |
|
 |
Simple to use, No complicated
program settings. |
|
 |
Timing Range, Memory Backup, Pulse
start and delay models are selectable by dip switch. |
|
 |
7 selectable timing range 9.99sec,
99.9sec, 999sec, 99.9Min, 999Min, 99.9Hrs & 999Hrs |
|
 |
Down Counting. |
|
 |
10 year Run time Memory Back up. |
 |
Selectable ON Delay/OFF Delay
mode. |
|
 |
opto isolated pulse start & Reset ON
Rear terminal. |
 |
High Accuracy. |
 |
Universal Supply 90 to 270V AC. |
 |
DPDT Relay output. |
|
|
|
|
|
SPECIFICATIONS |
|
Model |
DT 271 |
DT 241 |
|
Dimension |
72mmx72mmx65mm |
48mmx48mmx90mm |
|
Cutout Dimension |
68x68mm |
44x44mm |
|
Display |
0.5” Red .3 Digit preset
value.
0.39” Green 3 Digit set value. |
0.39” Red 3 Digit present
value.
0.3” Green 3 Digit set value. |
| |
|
Input
Accuracy |
±0.25% |
|
Range
|
Selectable By
9.99Sec
Dip Switch
99.9Sec
999Sec
99.9Min
999Min
99.9Hrs
999Hrs |
|
Memory Back up |
10 years Run time holding Memory Back up. |
|
Time
Setting |
By Front key switch |
|
Delay Mode |
ON Delay, OFF Delay selectable By Dip
switch |
|
Start |
Power on start, pulse start selectable.
(Rear Terminal) |
|
Reset Input |
Front panel Reset(3 Sec), Rear terminal
opto isolated Reset and power on reset. |
|
Counting Direction |
Down Counting |
|
STATUS Indication |
Relay on L.E.D |
|
Relay Output |
1 DPDT, 5A, 230V AC |
|
Supply |
90 to 270V AC, 50 Hz. |
|
Operating Temp& Humidity |
0 to 500C / 90% RH |
|
|
|
|
Top |
| Timer |
|
Model DT-70A |
|
| |
|
SPECIFICATIONS |
 |
4 Digit Display. |
|
 |
Front key configurable Universal
Time, Memory Back up, Pulse start and delay modes. |
|
 |
Timing Range 99.99sec, 999.9sec,
9999sec, 99.59hrs min, 9999min, 999.9hrs & 9999hrs. |
 |
Selectable UP / DOWN Counting. |
|
 |
ON delay, OFF delay, Cycle ON
First, & Single short cyclic. |
|
 |
Dual Relay output. |
 |
10 years Run time memory Backup. |
|
 |
Start, Reset & Hold facilities are
provide ON Rear terminal. |
 |
Universal Operating Supply. |
|
|
|
|
|
SPECIFICATIONS |
|
Model |
DT 70A |
|
Dimension |
72mmx72mmx110mm |
|
Cutout Dimension |
68x68mm |
|
Display |
0.5”
Red 4 digit
7 segment L.E.D |
| |
|
Input
Accuracy |
±0.05% |
|
Range
|
Front Key 99.99Sec
Selectable 999.9Sec
9999Sec
99.59MinSec
999.9Min
9999Min
99.59HrsMin
999.9Hrs
9999Hrs |
|
Memory Back up |
10 Years runtime holding Memory Backup. |
|
Time
Setting |
By
Front key Switch. |
|
Delay Mode |
ON
Delay, OFF Delay, Cyclic ON First & one short cyclic. |
|
Start |
Power ON start, Pulse start (Rear
Terminal) |
|
Hold |
Provided ON Rear terminal |
|
Reset Input |
Front panel Reset(3 Sec), Rear terminal
and power ON reset. |
|
Counting Direction |
UP/DOWN Selectable |
|
STATUS Indication |
ON Delay, OFF Delay by L.E.D Indication |
|
Relay Output |
2 SPDT Relay 5A,230V AC |
|
Supply |
90 to 270V AC, 50Hz. |
|
Operating Temp& Humidity |
0 to 500C/90%Rh |
|
|
|
|
|
|
Top |
|
|
|
|
Designed & Maintenance by : Hood Technologies Pvt Ltd |
|
 |