Calibrator
We are one of the leading suppliers of Calibrator that have got usage in various Industries, Testing centres and other such places. These Calibrator are made as per the laid industry quality standards and checked on the basis of their robust construction, Accuracy, Precision, Speed and other features.
 |
Ultra Low Temperature Bath
Model: TCAL 080
- Range from Ambient to -80°C
- Working Range from -40°C to -80°C
- Resolution Range 0.1°C
- Stability ± 0.1°C
- Uniformity ± 0.1°C
- Working chamber size W/H/D, 100mm / 190mm
- Cooling medium IPA
- Multi hole provision to calibrate different dia sensors and Thermometers
- 100mm Well Depth / Multi Hole
- NABL Accredited calibration certificate
|
 |
Low Temperature Bath
Model: TCAL 040
- Working Range from Ambient to -40°C
- Resolution Range 0.1°C
- Stability ± 0.1°C
- Uniformity ± 0.1°C
- Working chamber size W/H/D, 100mm / 190mm
- Cooling medium Glycol
- Multi hole provision to calibrate different dia sensors and Thermometers
- NABL Accredited calibration certificate
|
 |
Sub Zero Calibrator
Model: TCAL 150
- Micro Controller Based Linearized High Accuracy
- Range of -15°C to 110°C
- Accuracy to ± 0.5°C
- Resolution 0.1°C
- Stability ± 0.1°C
- RS 232 Interface
- No liquids safe & dry calibration
- 100mm Well Depth / Multi Hole
- 19mm Well Dia
- Temperature switch test
- Power requirement 230VAC / 50Hz / 500 Wats
- Light weight and rugged
- NABL Accredited calibration certificate
|
 |
Liquid Calibration Bath
Model: TCAL 150
- Range of 30°C to 250°C
- Stability ± 0.1°C
- Uniformity ± 0.1°C
- Working chamber dia / depth 100mm / 140mm
- Temperature medium silicon oil
- Power requirement 230VAC / 50Hz / 600 Wats
- NABL Accredited calibration certificate
|
 |
Dry Block Temperature Calibrator
Model: TCAL 1350 / 1650
- Micro Controller Based Linearized High Accuracy
- Range of -15°C to 110°C
- Accuracy to ± 0.5°C
- Resolution 0.1°C
- Stability ± 0.1°C
- Power requirement 230VAC / 50Hz / 600 Wats / 1200Wats
- RS 232 Interface
- Well depth / dia 110mm / 25mm
- No liquids safe & dry calibration
- Temperature switch test
- Multi hole insertion tube to suite different O.D sensors
- Light weight and rugged
- NABL Accredited calibration certificate
|
 |
High Temperature Dry Block Calibrator
Model: TCAL 11200
- Micro Controller Based Linearized High Accuracy
- Range from 300°C to 1200°C
- Accuracy to ± 3°C
- Resolution 0.1°C
- Stability ± 0.1°C
- RS 232 Interface
- 150mm well depth
- Multi hole insertion tube to suite different O.D sensors
- Temperature switch test
- Power requirement 230VAC / 50Hz / 600 Wats / 1200Wats
|
 |
High Temperature Bath
Model: TCAL 11500
- Temperature Range from 300°C to 1200°C
- Resolution 1°C
- Stability ± 1°C
- Interchangeable Multi hole thermowells
- Stability ± 0.1°C
- Silicon carbide Heating element
- Power requirement 230VAC / 50Hz / 3000VA
- Semi portable
- NABL Accredited calibration certificate
|
 |
Portable Black Body Source
Model: BCAL 1350
- For Calibrating medium range non contact IR Thermometer
- Temperature Range from 50°C to 350°C
- SLarge Aperture area mm
- High Resolution 0.1°C
- Stability ± 1°C
- Power requirement 230v AC / 50Hz / 600VA
- Light weight suitable for field calibration
- Weight: 7kg
- NABL Accredited calibration certificate
|
 |
Portable Black Body Source
Model: BCAL 1650
- For Calibrating medium range non contact IR Thermometer
- Temperature Range from 100°C to 650°C
- Large Aperture area mm
- High Resolution 25°C
- Stability ± 0.2°C
- Power requirement 230v AC / 50Hz / 1200VA
- Light weight suitable for field calibration
- Weight: 9kg
- NABL Accredited calibration certificate
|
 |
High Temperature Black Body Source
Model: BCAL 11200
- For Calibrating medium range non contact IR Thermometer
- Temperature Range from 500°C to 1200°C
- Aperture area 50 mm
- High Resolution 1°C
- Stability ± 1°C
- Temperature controlled by Auto-tune Fuzzy logic PID
- Power requirement 230v AC / 50Hz / 2000VA
- Light weight suitable for field calibration
- Weight: 13kg
- NABL Accredited calibration certificate
|
 |
Semi Standard Platinum Resistance
Model: SSPRT
- Temperature Range from -80°C to 660°C
- T6mm O.D, available length 300mm, 450mm & 600mm
- 4wire output, cable length meter or as request
- Outer sheath SS-316
- Accuracy class A, 1/3 Din & 1/10 Din
- Low Drift, fast response and long term stability
- NABL Accredited calibration certificate
|
 |
Master Thermocouple
Model: MTC
- Temperature Range upto1200°C and 1500°C
- Accuracy class K/N Type (0 to 1500°C ± 1.1°C or 0.4% ) S/R type (0 to 1500°C ± 0.6°C or 0.1%)
- 6mm outer dia, available length 300mm, 450mm and 600mm
- Outer sheath inconel or ceramic
- Low drift, fast response and long term stability
- NABL Accredited calibration certificate
|
 |
Precision Humidity / Temperature Calibration System
Model: HCAL 1100
- Humidity range 15% to 95% RH
- Temperature range 15°C to 50°C
- Humidity resolution 0.1% RH
- Temperature resolution 0.1°C
- Accuracy ± 1.5% RH / 0.3°C
- Uniformity of chamber better than 0.5% RH/0.2°C
- No external air or Nitrogen
- Technology by flow control Technique
- Versatile, fast and accurate
- Interchangeable front door to suitable for calibration of Humidity / Temperature sensor, Transmitters, Portable Indicators, etc
- NABL Accredited calibration certificate
|
|
|
|
|
 |